Search results for " endovascular aneurysm repair"

showing 10 items of 12 documents

Multiple periscope and chimney grafts to treat ruptured thoracoabdominal and pararenal aortic aneurysms

2011

Purpose: To report midterm outcomes after urgent endovascular repair of ruptured pararenal or thoracoabdominal aortic aneurysms using multiple periscope and chimney grafts to preserve renovisceral branch perfusion and facilitate aneurysm exclusion. Methods: Nine consecutive men (mean age 72614 years, range 40–88) presenting with ruptured thoracoabdominal (n56), pararenal (n52), or infrarenal (n51) aortic aneurysm underwent urgent endovascular repair with at least 1 periscope graft delivered via a transfemoral access; chimney grafts were installed from an axillary access. In all, 17 periscope and 7 chimney grafts were used to reperfuse 11 renal and 13 visceral arteries in the 9 patients. The…

AdultMalemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic RuptureLess invasive610 Medicine & healthRuptured Aortic AneurysmProsthesis DesignEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortography2705 Cardiology and Cardiovascular Medicinelaw.inventionBlood Vessel Prosthesis ImplantationlawmedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingChimneyAgedRetrospective Studiesendodebranching renovisceral arteries chimney graft periscope graft stentgraft endograft ruptured aortic aneurysm ruptured thoracoabdominal aortic aneurysm ruptured pararenal aortic aneurysm ruptured AAA endovascular aneurysm repairAged 80 and overAortic Aneurysm Thoracicbusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresChimney graftBlood flowMiddle AgedSurgeryBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgeryTreatment Outcomecardiovascular systemSurgeryFemaleStentsRadiologyPeriscopeCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAortic Aneurysm Abdominal
researchProduct

Predilation technique with balloon angioplasty to facilitate percutaneous groin access of large size sheath through scar tissue

2017

Purpose Percutaneous remote access for endovascular aortic repair is an advantageous alternative to open access. Previous surgery in the femoral region and the presence of synthetic vascular grafts in the femoral/iliac arteries represent major limitations to percutaneous remote access. The aim of this study was to evaluate an original technique used for enabling percutaneous remote access for thoracic or abdominal endovascular aortic repair in patients with scar tissue and/or a vascular graft in the groin. Methods Twenty-five consecutive patients with a thoracic (11/25; 44%) or an aortic aneurysm (14/25; 66%) and with a synthetic vascular graft in the groin (16/25; 64%) or a redo groin acce…

MalePercutaneousmedicine.medical_treatment030204 cardiovascular system & hematologyBalloonEndovascular aneurysm repairSettore MED/22 - Chirurgia Vascolarecalcificationendovascular aneurysm repairAortic aneurysm0302 clinical medicinesheathprosthetic graftballoon angioplastyVascular closure device030212 general & internal medicineAged 80 and over10042 Clinic for Diagnostic and Interventional RadiologyVascular Access Deviceultrasonographyvascular closure deviceGeneral MedicineEquipment Design2746 SurgeryBlood Vessel Prosthesimedicine.anatomical_structureTreatment OutcomeFemaleRadiologyCardiology and Cardiovascular MedicineVascular Access DevicesHumanmedicine.medical_specialtycomplication610 Medicine & healthGroin2705 Cardiology and Cardiovascular MedicineAneurysm; balloon angioplasty; calcification; complications; endovascular aneurysm repair; infection; prosthetic graft; sheath; ultrasonography; vascular closure devices; Aged; Aged 80 and over; Angioplasty Balloon; Aortic Aneurysm Abdominal; Aortic Aneurysm Thoracic; Blood Vessel Prosthesis; Blood Vessel Prosthesis Implantation; Catheterization Peripheral; Cicatrix; Equipment Design; Female; Groin; Humans; Male; Treatment Outcome; Ultrasonography Interventional; Vascular Access Devices; Surgery; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine03 medical and health sciencesBlood Vessel Prosthesis ImplantationCicatrixBlood vessel prosthesisAngioplastyCatheterization Peripheralmedicine2741 Radiology Nuclear Medicine and ImagingHumansRadiology Nuclear Medicine and imagingUltrasonography InterventionalAgedGroinAortic Aneurysm Thoracicbusiness.industrymedicine.diseaseAneurysminfectionSurgery10020 Clinic for Cardiac SurgeryBlood Vessel ProsthesisSurgerybusinessAngioplasty BalloonAortic Aneurysm Abdominal
researchProduct

Mid- and Longer-term Follow up of Chimney and/or Periscope Grafts and Risk Factors for Failure

2016

Objective The aim was to report on chimney and periscope grafts (CPGs) and their mid- and longer-term outcomes when they are used to preserve reno-visceral artery (RVA) perfusion in endovascular repair of pararenal (PRAAs) or thoraco-abdominal aortic aneurysm (TAAAs). In addition, factors associated with CPG failure are presented. Limited data exist on the outcomes of CPGs, and mid- and long-term results are generally not reported. Methods This was a prospective study in a cohort of 100 patients with PRAA (69) or TAAA (31). A total of 224 (mean 2.24 per patient) RVAs were preserved with 136 (61%) chimney and 88 (39%) periscope grafts. CPGs were constructed mainly using self expandable stent…

MalePercutaneousmedicine.medical_treatment030204 cardiovascular system & hematologyEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysm0302 clinical medicineRenal ArteryRisk FactorsOcclusion030212 general & internal medicineTreatment FailureProspective cohort studyAortaPararenal aortic aneurysm10042 Clinic for Diagnostic and Interventional RadiologyReno2746 SurgeryAortic AneurysmFemaleRadiologyCardiology and Cardiovascular Medicinemedicine.medical_specialty610 Medicine & health2705 Cardiology and Cardiovascular Medicine03 medical and health sciencesEndovascular aneurysm repairabdominal aortic aneurysmAneurysmChimney and periscope graftChimney and periscope graft; Complex aortic aneurysm; Endovascular aneurysm repair; Pararenal aortic aneurysm; Reno-visceral arteries; Thoraco-abdominal aortic aneurysm; Cardiology and Cardiovascular Medicine; SurgerymedicineHumansAgedRetrospective StudiesReno-visceral arterieThoraco-abdominal aortic aneurysmbusiness.industryComplex aortic aneurysmStentRetrospective cohort studyThoracomedicine.diseaseSurgeryvisceral arteriesSurgeryVascular GraftingbusinessFollow-Up Studies
researchProduct

Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients

2017

Purpose Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). Methods Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. Results Fort…

MaleTime FactorsEndoleakComputed Tomography Angiographymedicine.medical_treatmentMid term resultsKaplan-Meier Estimate030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairAortic aneurysmPostoperative Complications0302 clinical medicineRisk FactorsOcclusionMedicine030212 general & internal medicineAortic arch aneurysm; Chimney graft/technique; Endoleak; Endovascular aneurysm repair; Parallel graft; Periscope graft; Surgery; Cardiology and Cardiovascular MedicineAged 80 and overeducation.field_of_studyHigh risk patients10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresMiddle Aged2746 SurgeryTreatment Outcomecardiovascular systemFemaleRadiologyCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyPopulation610 Medicine & healthProsthesis DesignAortographyRisk AssessmentDisease-Free Survival2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationEndovascular aneurysm repair03 medical and health sciencesAneurysmmedicine.arteryHumanseducationAgedRetrospective StudiesAortaAortic Aneurysm ThoracicParallel graftAortic arch aneurysmbusiness.industryPatient SelectionChimney graft/techniquemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac SurgerySurgeryPeriscope graftSurgerybusinessEuropean Journal of Vascular and Endovascular Surgery
researchProduct

Hybrid Endograft Solution for Complex Iliac Anatomy

2010

The purpose of this study was to evaluate single-center results with selective use of Gore Excluder limbs (W.L. Gore & Associates, Flagstaff, AZ) in a Cook Zenith body (Cook Inc, Bloomington, IN) for elective endovascular abdominal aortic aneurysm (AAA) repair. A prospectively held database for patients with AAA, who were treated endovascularly between March 1999 and July 2008, was queried for patients treated with a Cook Zenith body and one or two Gore Excluder limbs. Indication, technical success, late limb occlusion, and disconnection were evaluated. From 276 patients who were treated with a Zenith body, 29 underwent repair with hybrid graft components with, in total, 41 Gore Exclud…

MaleTime FactorsOCCLUSIONmedicine.medical_treatmentSettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairendovascular aneurysm repairAortic aneurysmOcclusionEVARAged 80 and overOUTCOMESmedicine.diagnostic_testGeneral MedicineAnatomyAbdominal aortic aneurysmTreatment OutcomeElective Surgical ProceduresFemaleRadiologyCardiology and Cardiovascular MedicineElective Surgical Proceduremedicine.medical_specialtyAortographyProsthesis DesignAortographyIliac ArteryBlood Vessel Prosthesis Implantationabdominal aortic aneurysm endovascular aneurysm repair Excluder limbs hybrid graft iliac tortuosityabdominal aortic aneurysmBlood vessel prosthesismedicineHumansExcluder limbsRadiology Nuclear Medicine and imagingAgedRetrospective Studiesbusiness.industryENDOVASCULAR REPAIRAORTIC-ANEURYSM REPAIRmedicine.diseaseSurgeryBlood Vessel Prosthesisiliac tortuosityFeasibility StudiesSurgeryhybrid graftSTENT-GRAFTSbusinessTomography X-Ray ComputedAbdominal surgeryAortic Aneurysm AbdominalVascular
researchProduct

Collected Transatlantic Experience From the PERICLES Registry: Use of Chimney Grafts to Treat Post-EVAR Type Ia Endoleaks Shows Good Midterm Results

2018

Purpose: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). Methods: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). O…

MaleTime Factorsabdominal aortic aneurysm; chimney graft; chimney technique; endoleak; endovascular aneurysm repair; juxtarenal aortic aneurysm; parallel graft; pararenal aortic aneurysm; periscope graft; snorkel graftmedicine.medical_treatmentJuxtarenal aortic aneurysm030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairendovascular aneurysm repair0302 clinical medicineRisk FactorsRetrospective analysisChimneyRegistries030212 general & internal medicineAged 80 and overEndovascular ProceduresChimney graftAbdominal aortic aneurysmEuropeTreatment Outcomesnorkel graftFemaleStentsjuxtarenal aortic aneurysmCardiology and Cardiovascular MedicineReoperationmedicine.medical_specialtyparallel graftendoleakperiscope graftProsthesis Designpararenal aortic aneurysmBlood Vessel Prosthesis Implantation03 medical and health sciencesabdominal aortic aneurysmchimney techniquemedicineHumansRadiology Nuclear Medicine and imagingAgedRetrospective Studiesbusiness.industrychimney graftmedicine.diseaseUnited StatesBlood Vessel ProsthesisSurgerySurgerybusinessAortic Aneurysm AbdominalJournal of Endovascular Therapy
researchProduct

A 12-Year Experience With Chimney and Periscope Grafts for Treatment of Type I Endoleaks.

2015

Purpose: To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). Methods: Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2–179). All patients had proximal/distal landing zones precluding any standa…

Malemedicine.medical_specialtyEndoleakmedicine.medical_treatmentparallel graftTarget vesselmorbidityperiscope graftEndovascular aneurysm repairpararenal aortic aneurysmSettore MED/22 - Chirurgia Vascolarelaw.inventionendovascular aneurysm repairBlood Vessel Prosthesis Implantationabdominal aortic aneurysmlawRecurrencethoracoabdominal aortic aneurysmMedicineHumansRadiology Nuclear Medicine and imagingIn patientChimneyself-expanding covered stentVascular PatencyAgedabdominal aortic aneurysm; chimney graft; endoleak; endovascular aneurysm repair; morbidity; mortality; parallel graft; pararenal aortic aneurysm; patency; periscope graft; reintervention; self-expanding covered stent; stent-graft; target vessel; thoracoabdominal aortic aneurysmreinterventionstent-graftbusiness.industryEndovascular ProceduresChimney graftchimney graftmedicine.diseasemortalityAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisSurvival RateTreatment OutcomeSurgeryFemalePeriscopeCardiology and Cardiovascular Medicinebusinesspatencytarget vesselAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Outpatient endovascular aortic aneurysm repair: Experience in 100 consecutive patients

2013

OBJECTIVES:: To present the safety, feasibility, costs, and patient satisfaction of outpatient endovascular aneurysm repair (EVAR). BACKGROUND:: Our experience in more than 1000 patients indicated that in technically uncomplicated EVAR procedures, the only need for hospitalization was for access vessel complications (bleeding or occlusion) requiring secondary procedures. These complications could always be identified within the first 3 hours after EVAR. METHODS:: Two-center retrospective analysis of prospectively gathered data on 100 consecutive elective outpatient EVAR cases (Outpt EVAR). Inclusion criteria for Outpt EVAR were as follows: asymptomatic clinical state, informed consent, trav…

Malemedicine.medical_specialtyPercutaneousmedicine.medical_treatment610 Medicine & healthEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareBlood Vessel Prosthesis ImplantationPostoperative ComplicationsPatient satisfactionAmbulatory CareHumansMedicineOutpatient clinicLocal anesthesiaambulant day endovascular aneurysm repair EVAR fast-track outpatient surgeryAgedRetrospective StudiesAged 80 and overbusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresStentMiddle AgedVascular surgerymedicine.diseaseSurvival AnalysisSurgery10020 Clinic for Cardiac Surgery2746 SurgeryStenosisTreatment OutcomeCosts and Cost AnalysisFemaleSurgerybusinessAortic Aneurysm Abdominal
researchProduct

Endovascular treatment options for complex abdominal aortic aneurysms

2015

Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …

Malemedicine.medical_specialtyRadiology Nuclear Medicine and ImagingTime Factorsmedicine.medical_treatmentCustom-made fenestrated endovascular aneurysm repairProsthesis DesignRevascularizationAortographyEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareBlood Vessel Prosthesis ImplantationAortic aneurysmAneurysmBlood vessel prosthesismedicine.arterymedicineHumansRenal arterychimney endovascular aneurysm repairVascular PatencyAgedRetrospective StudiesAged 80 and overbusiness.industryhomemade fenestrated endovascular aneurysm repairEndovascular Procedureshomemade fenestrated endovascular aneurysm repair; Custom-made fenestrated endovascular aneurysm repair; chimney endovascular aneurysm repairPerioperativeMiddle Agedmedicine.diseaseBlood Vessel ProsthesisSurgeryVisceraTreatment OutcomeRegional Blood FlowFemaleStentsRadiologyTomography X-Ray ComputedbusinessCardiology and Cardiovascular MedicineBlood Flow VelocityAortic Aneurysm AbdominalAbdominal surgery
researchProduct

Chimney endografting for pararenal aortic pathologies using transfemoral access and the lift technique

2013

Purpose: To present a technique for transfemoral implantation of parallel grafts into the renal arteries in patients with anatomy or morphology that blocks standard antegrade chimney graft delivery. Technique: In a totally percutaneous approach, a 5-F pigtail angiographic catheter is passed into the aorta above the renal arteries via a 0.035-inch hydrophilic guidewire, followed by an 8-F sheath. The target vessel is cannulated with the hydrophilic wire followed by a 5-F reverse curve catheter; the wire is changed for a Rosen wire. The main stent-graft body is delivered and parked at the level of the aortic bifurcation. The Viabahn chimney endograft is advanced ~1 to 2 cm into the target ren…

Settore MED/22 - Chirurgia Vascolareendovascular repair abdominal aorta pararenal aorta aneurysm endovascular aneurysm repair stent-graft chimney graft chimney technique deployment technique self-expanding stent-graft
researchProduct